MYTHEN2 R 系列

Description

DECTRIS® MYTHEN2 strip detectors bring synchrotron-like detection to the lab for all X-ray diffraction, scattering, and spectroscopy techniques. Their radiation hardness and maintenance-free operation make these detectors the perfect choice for academic research, multi-purpose service laboratories, portable diffractometers, and industrial sites that employ Good Manufacturing Practice (GMP) and Good Laboratory Practice (GLP) rules.

MYTHEN2 R offers the narrowest strip width (50 μm) on the market, providing unprecedented signal resolution. Single-photon counting eliminates dark current and readout noise while delivering superior data. MYTHEN2 R detectors also combine noise-free performance with high quantum efficiency for the widest X-ray energy range: from Ti to Ag. This unique combination of features will help you make the most of weak laboratory sources by maximizing the signal-to-noise ratio and minimizing measurement and data processing times.

Specification

SG 匯率表
幣別
金額換算
新台幣 (TWD)
0
美金 (USD)
0
歐元 (EUR)
0
瑞士法郎 (CHF)
0
日圓 (JPY)
0
人民幣 (CNY)
0
英鎊(GBP)
0
澳幣(AUD)
0
新加坡幣(SGD)
0
加拿大幣(CAD)
0
紐元(NZD)
0

  • Fast & accurate: these detectors offer noise-free detection at the highest commercially available count rate for an extended energy range (from 4 to 40 keV). 
  • Modular & compatible: individual modules are easy to combine to build larger systems. The detectors also offer optional vacuum capability. 
  • Reliable: detector performance will be maintenance- and service-free. Delivery terms are guaranteed, thanks to streamlined industrial production and top-notch support.
 
→ MYTHEN2 R 1K
This multipurpose device with unsurpassed resolution will meet the requirements of all X-ray diffraction, scattering, and spectroscopy techniques.
→ MYTHEN2 R 1D​
This detector is the perfect choice for portable diffractometers, stress measurements, and XRD benchtop systems.
 

Detector Specifications*

  MYTHEN2 R 1K MYTHEN2 R 1D

Strip width

 [

µm

 ]

50

50

Strip height

 [

mm

 ]

8

8 (450 μm only)
4 (320 μm only)

Active area (W x H)

 [

mm²

 ]

64 x 8

32 x 8 (450)
32 x 4 (320)

Energy range (depending on the sensor thickness)

 [

keV

 ]

5 - 40 (320)
6.6 - 40 (450)
7.4 - 40 (1,000)

4 - 40 (320)
6.6 - 40 (450)

Threshold range (depending on the sensor thickness)

 [

keV

 ]

4.5 - 20 (320)
5.5 - 20 (450)
6.0 - 20 (1,000)

3.5 - 20 (320)
5 - 20 (450)

Frame rate (max.)

 [

Hz

 ]

100

100

Count rate (max.)

 [

ph/s/strip

 ]

107

107

Readout time

 [

µs

 ]

89

89

Strips per module

 [

strips

 ]

1,280

640

Sensor material

Silicon (Si)

Silicon (Si)

Sensor thickness

 [

µm

 ]

320, 450, or 1,000

320 or 450

Point-spread function

 [

strips

 ]

1

1

Vacuum compatibility

Optional

Optional

Module dimensions (W x H x D)

 [

mm³

 ]

70 x 62 x 22

36 x 62 x 22

Cooling method

Air

Air

*All specifications are subject to change without notice.

(0)